If you have a fire door, you will need fire door ironmongery. Specifying the right ironmongery and door hardware is crucial to ensure that the fire rating of a door is maintained and, for the safety of the building’s occupants. The ironmongery in this section of the website is specifically for use on fire doors; the products are CE Marked and Certifire approved and comply with relevant British Standards.
BS EN 1634 Standard
BS EN 1634 is a European fire test standard for all fire door CE Marked ironmongery products. Anything CE marked must also Fire Doors in the UK are typically tested with just three fire rated products: 3 hinges, a door closer and a lock or latch. The bolt in a lock is wired back so that this does not contribute to holding the door closed. This then allows for the door manufacturer to be able to test two key points at the same time:
A fire door must prove that it can withstand a fire attack for a specified amount of time, in order to successfully achieve its fire rating. This means that hot gasses and flames are not to pass through for the duration of a fire test. E.g. FD30 doors should have a 30 minute fire resistance and are tested for 36 minutes, FD60 Doors should have a 60 minute fire resistance and are tested for 67 minutes. This is known as Fire Door Integrity.
Fire Door Integrity does not include the passage of smoke and at the beginning of a fire test, smoke is pushed through the gaps between the door and frame and the meeting styles on a pair of double doors. Any intumescent that is fitted to these doors then expands and fills the gaps to reduce the passage of smoke through the door to 0 until the end of the expected fire rating where the door warps and burns completely.
Fire Rated Hinges
Fire doors should be fitted with 3no. 102mm hinges that are CE marked under Fire Regulations. Fitting 3 hinges will also help stop the door from warping – for extra tall doors over 2200mm, four hinges may be used to prevent this. Occasionally 2 hinges may be used but only with supporting fire test evidence. Fire door hinges must remain attached to the door during a fire test, even if the timber around them is charred. Some steel and Brass hinges are acceptable for use on FD30 30-minute fire doors whilst only steel hinges should be use on FD60 60-minute fire doors. Under BS EN1935:2002, any hinges fitted to a fire door, must be able to achieve the appropriate fire rating. They must also not impede any door closers that may be fitted to the doors and overcome any seals and resistance from latches. Intumescent hinge pads should be used with all hinges on fire doors, even if they are CE Marked, or full compliance with fire ratings.
Fire Rated Door Closers
All door closers fitted to a fire door, whether concealed or overhead, must be CE Marked and suitable for the fire rating of a door. You must not install any ironmongery that has a fire test rating lower than that of the door. For example, if you have a 60-minute fire rated door, you cannot install anything that has a lower fire rating like products with a 30-minute fire rating. You can, however, install a 60-minute fire rated product on a 30-minute fire rated door.
Door Closers should be performance tested to EN1534 and Fire Tested to EN1634 in order to be CE marked. They should also be a minimum of a power size 3 (EN3) when fitted to a fire door.
If a door is to be held open, then an electromagnetic door closer linked up to the fire alarm interface should be used.
Digital Locks
There is no performance test to which Digital Locks should comply, however fire rated digital locks should be supplied with appropriate intumescent and be fire tested to EN 1634 and EN 476.
Locks & Latches Locks
Any lock or latch installed on a fire door must be CE Marked and tested to BS EN 12209. Fire Rated mortice locks and latches can be installed with intumescent jackets and any cut made into the door to accommodate them must be minimal.
Fire Rated Intumescent
Intumescent Seals have an important job of expanding to fill gaps around the edge of the doors to prevent the spread of smoke and fire. It contributes to the fire rating of a door as it slows down the ability of flames to pass through the door. When a fire door and seals are fitted correctly, any gaps around the top and sides should be less than 4mm thick – the seals will expand to fill these in the event of a fire.
Any hinges and morticed locks and latches should be installed with appropriate intumescent sheets or pads. These act as a barrier between the product and the door to ensure that heat transfer is delayed. Always check the fire test certificates to ensure full compliance with any given fire rating.
Fire Rated Accessories & Signage
Accessories on Fire Doors must not affect the integrity of a fire door. There are products like door viewers for example, that have been fire tested with intumescent that are appropriate for use on such doors.
Signage for fire door is mandatory and falls under BS 5499-5:2002 Approved Document B. All fire doors must display signs that either read “Fire Door Keep Locked” or “Fire Door Keep Shut” depending on the function of the door. There are no performance standards for signage, and they should be face fixed to the fire door.
Fire Rated Lever Handles
Fire Rated lever handles should conform to BS EN1906 – the British Standard for Door Furniture. This standard covers all door furniture with backplates or roses. There does not necessarily need to be a CE marking but the handle set should have been put through fire testing and given a Grade 3 for durability and a Grade 1 for Fire Rating.
Fire Rated Pull Handles
Pull Handles, although are never CE Marked, should be tested under BS 476, which is the British fire test standard on building materials and building structures. BS EN476 grades the level of resistance that an ironmongery product has, using a class system. During this test, products are set alight with a pilot flame and then extinguished after 1 minute. The material of the product might start to burn and the test ends when either the flame front reaches a 825mm reference point or after 10 minutes – whichever comes first. The flame is then classified according to the time that the flame crosses certain reference points, the extent of flame spread during the first 1.5minutes of the test, the maximum distance the flame spread (10 minute/825mm limit) and the time taken for the flame to spread.
Intumescent Letterboxes
If you must install a letterbox on a fire door, you must only use an intumescent letterbox so as not to affect the integrity of the fire door.
Active filters
Code: NB2801SS
A 75mm diameter Fire Door Keep Shut Sign in satin stainless steel.
Code: LB0116SS
ARRONE AR8100 Euro Profile Sashlock with a DIN standard 60mm backset.
Code: FC2043SS
The ARRONE AR961/67 Stainless Steel Euro Profile Escutcheon is a grade 304 stainless steel euro profile escutcheon complements the AR961 lever on round rose door furniture.
Code: BB7008SS
This fire rated stainless steel lever action flush bolt is available with radius or square faceplates and in a variety of sizes. Select from the drop down menus below.
Code: LB6256SS
The ARRONE AR8019 Heavy Duty Tubular Mortice Latch is suitable for sprung and some unsprung lever furniture. Comes complete with both Satin Chrome and Polished Brass forends and strike plates.
Code: XB8471XX
A universal intumescent kit to suit tubular mortice latches (Latch not included).
Code: DCG1500
The GEZE TS1500 EN 3/4 Door Closer is a surface mounted rack & pinion overhead door closer which is approved for use with single-action doors with leaf widths of up to 1100 mm and for use on smoke and fire doors. The closing speed (3-4) and latching action are adjustable.
Code: DCG2000NVBC
The GEZE TS2000NVBC EN 2-4 Door Closer is a rack & pinion overhead door closer which is approved for use on single action doors with leaf widths of up to 1100 mm and suitable for smoke and fire doors. It comes with variable Power Size EN 2-4 and adjustable closing speed, latching action and backcheck.
Code: NB2401PA
A 75mm diameter Fire Door Keep Shut Sign in satin anodised aluminium.
Code: IB2107SE
The TOP37 Rebated Drop Down Acoustic Door Seals are a rebated model for timber doors. They have been acoustically tested to achieve up to 37dB Rw.
Code: DCD68
The DORMA TS68 EN2-4 Door Closer is a rack and pinion overhead door closer suitable for parallel arm and frame fitting. This unit is non-handed and in a silver finish. It is tested to BS EN 1154, for fitting to standard internal doors.
Code: IBT726
The Trend rebated drop down seal is available in a variety of lengths. It is trimmable by up to 200mm, with a maximum drop of 14mm, and is fire tested to FD60.
Code: DCH1500SE
The ARRONE AR1500 EN2-4 Door Closer is dual handed and suitable for universal door applications. It has adjustable closing and latch speed and a 120 minute fire rating. It is a power size 2-4 and comes with backcheck; meaning that it is suitable for high traffic doors. This closer is low budget and extremely versatile.
Code: DCH5500SE
The ARRONE AR5500 is a heavy duty EN2-5 Overhead Door Closer, suitable for use on Fire Doors.
Code: KITLKBE20
The bathroom 'Lift To Lock' kit is supplied as a complete kit including the mortice bathroom lock, stainless steel lever handles and signage. To lock the door from the inside you simply lift the lever and to egress, you simply depress the inside lever, making it an ideal solution for accessible toilets. Use the drop down menu to choose the finish and fire rated or non-fire rated.
Code: ESAL900FR
The AL900 electric strike is 12/24V AC/DC selectable, fail safe/ fail secure reversible and fire rated for use on FD30 and FD60 doors.
The fire rated option comes supplied complete with the 1mm intumescent kit.
Code: DORGARDB
The Dorgard fire door retainer is a BS EN 1155 compliant, wire-free solution for legally holding open fire doors that you can install in under 5 minutes.
Select from black or white finish housing (floor fixing foot not included).
Code: LB1976SC
The ARRONE AR7006 Euro Profile Mortice Deadlock Case is a euro profile mortice deadlock case, complete with a heavy duty brass deadbolt and bolt through fixing holes.
Code: XB8466XX
Intumescent Flush Bolt Kit for use with lever action flush bolts.
Code: EK3535-MP5-SCP
The MP5 5 Pin Euro Key & Thumbturn Cylinder is a 70mm or 80mm 5 pin euro profile cylinder with thumbturn and 3 keys.
Code: FC20469SS
The ARRONE AR961/69D Stainless Steel Disabled Turn & Indicator grade 304 stainless steel bathroom turn, complements the AR961 lever on round rose door furniture. It has a 52mm diameter with 38mm fixing centres and it is supplied with a 5mm spindle and wood screws.
Code: XB8465XX
This is an intumescent lock jacket to suit DIN standard mortice locks, made of black graphite. Select 60mm or 80mm backset.
Code: XB8490XX
These 1mm Interdens intumescent hinge pads are for use with the Royde and Tucker H102 and H208 hi-load hinges. 2no pads are required per hinge.
Code: DLH525
The ARRONE AR525 & AR526 Fire Rated Mechanical Digital Locks are robust push-button mechanical digital locks suitable for internal and external applications.