DORMA G-N Cushioned Limit Stay - 35800093
Code: DCD93GNCLS
The DORMA G-N 35800093 Limiting Stay helps minimise damage from doors that are opened normally, against adjacent walls.
Read More
We offer a selection of door closers from leading manufacturers such as GEZE, dormakaba, Briton, and Arrow. Closers are available to suit all budgets and situations including both manual and automatic doors as well as electromagnetic hold open and swing free applications. The range is complemented with concealed door closers from Perko for use in situations where a clean, aesthetically pleasing finish to the door is required.
Approved Doc M and BS8300: Relates to accessibility and the code of practice in the design of buildings to meet the needs of disabled people. Swing free door closers with adjustable power sizes can help with ease of access throughout a building and will often be specified on new building projects.
Part B: To do with fire safety – electromagnetic door closers and holders are Part B compliant.
We try to ensure that choosing the right door closer for you is as easy as possible and simplify technical terminology so that you know what you’re purchasing. If you are in any doubt and would like assistance with your choice, please contact the sales team on 01305 263300 or email [email protected]
Backcheck – Is the cushioning effect you feel when the door is swung open and is prevented from slamming into the wall behind it. It’s a useful feature to ensure that door hardware and the door itself are given a certain level of protection from misuse. Closers with backcheck are also referred to as soft door closers.
Delayed Action/Delayed Close – In simple terms, this means the length of time it takes for the door to close after being opened. It’s often a desirable feature for Care Homes or areas where it may take people a little more time to get through the door unharmed. This function could also be referred to as a door soft closer.
Power Size – This is either fixed at a set number or variable (adjustable). The power size required is determined by the door weight and width. (See Power Size Table below).
Closing Speed – This is the adjustment for the general speed of the door closing. Installers often make the mistake of adjusting this to close the door when first installing a closer, the Power Size should always be adjusted first.
Latching Action – This is adjustable and refers to the final few degrees of closing. This is beneficial to overcome any issues with the latch or seal on a door.
Mechanical Hold Open – A Hold Open Arm can be used on door closers to achieve a rigid hold open function, however these must never be used on Fire Doors.
Hold Open – Electromagnetic Hold Open: Ideal for use on Fire Doors; the Hold Open function means that the door is held open permanently at a fixed angle (unless released by the fire alarm activation). Usually this function is provided in the cam being used, the arm itself or a mechanism inside the slide channel.
Electromagnetic Free Swing – This function means that the door with the electromagnetic closer will act like a door that doesn’t have any closer on it. It means that the door will stay open at whatever angle it is left at but will close in the event of a fire. It’s a particularly good feature to use on Care Home Bedroom Doors when hold open function would cause privacy issues and it meets the barrier-free needs of less-able users.
EN Power Size |
Max. Door Weight (kg) |
Max. Door Width (mm) |
1 |
20 |
750 |
2 |
40 |
850 |
3 |
60 |
950 |
4 |
80 |
1100 |
5 |
100 |
1250 |
6 |
120 |
1400 |
7 |
160 |
1600 |
The above guide is just a guide, based on optimal testing conditions and does not take into consideration any site variables such as the following:
As well as the above, when making a decision on what type of door closer you require, it is a good idea to think about the following:
If you want to read more, head over to our complete guide to selecting the right door closer.
Arms and Mechanisms:
See overhead door closers for more information.
There are a wide variety of door closers available, click through below to find out more:
Active filters
Code: DCD93GNCLS
The DORMA G-N 35800093 Limiting Stay helps minimise damage from doors that are opened normally, against adjacent walls.
Code: DCD93GNHO
This DORMA G-N Mechanical Hold Open Unit 18570000 is for use with the TS91, TS92 and TS93 Overhead Door Closers.
Code: ZDM8066
The DORMA 8066 Top Centre - Complete Unit for use with DORMA Double Action Floor Springs.
Code: DCAA200A
The DC200A overhead door closer has adjustable power size EN 2-4 and backcheck function. It's suitable for use on timber and metal fire doors.
Code: DCD80EMB
The DORMA BTS80EMB EN4 Electromagnetic Hold Open Floor Spring has electrohydraulic hold-open and integral pressure compensation feature for multipoint hold open between 65° and 175°. With adjustable, hydraulically controlled closing speed, adjustable latching action and backcheck.
Code: DCB2320
The Briton 2320B.T EN 2-4 cam action slide arm door closer is suitable for surface mounting on the pull side of the door and can be installed on fire rated doors.
Code: DC8550
The DORMA 8550/1 Universal Side Load Floor Pivot is a floor pivot set (end-load installation) for use with transom door closers and top rails with a minimum 21mm channel depth and 35mm width.
Code: TS91B
The DORMA TS91B EN3 Cam Action Door Closer is an easy to install slide channel door closer with a fixed power size EN3. Silver finish with a Contur design, it is both stylish and functional.
Code: DAPDA80
A DORMA Double Action Floor Spring Accessory Pack for use with DORMA floor springs on Double Action Doors.
Code: DCB996S
A Solenoid to suit Briton 996 24V DC operation to suit the Briton 996 series door closers.
Code: DHEM500A
The DORMA EM500A - 24V DC Electromagnetic Door Retainer is an electromagnetic hold open door retainer that is suitable for use with overhead door closers and floor springs.
Code: DCD93BGEMF
A DORMA G-EMF 64080001 Hold Open Electromagnetic Slide Channel Arm for use with the TS91, TS92 and TS93 Door Closers.
Code: DCD80F-L
The DORMA BTS80F EN4 Non Hold Open Floor Spring is a universal floorspring and comes complete with backcheck. Available as single action or double action, it offers fully adjustable closing speed. It is CE Marked and Certifire Approved CF 127.
Code: DCDBODY
A replacement mechanism for the dormakaba TS73EMF and TS73EMFS door closers.
Code: IR996FL
Replacement Armoured Loop To Suit Briton 996 - 330mm flexible cable loop.
Code: DCAA140A
The Assa Abloy DC140A-1 overhead door closer is power size adjustable by template. It is suitable for use on fire doors and it is perfect for narrow doors.
Code: DCDCL
A Replacement DORMA Distributor Box and Cable for use with DORMA Electromagnetic Door Closers.
Code: DC8552
The DORMA 8552/3 Universal End Load Floor Pivot is a floor pivot set (side-load installation) for use with the RTS85 and top rails with a channel depth of 18-20mm.
Code: DHEMKC
Geofire Keeper & One Metre Chain Plate for use with Geofire Door Retainers.
Code: TS93EB
The dormakaba TS93EMF electromagnetic door closer features hold open, backcheck, and delayed action functions. Certifire Approved for use on fire rated doors. Use the drop down menu to select your preferred power size range.
Code: DCD99SF
The DORMA TS99FL electromagnetic door closer with swing free function has a Contur design cover and guide rail. Use the drop down menu to select either frame or standard mounting.
Code: ZDM7421
The DORMA 7421 Double Action Door Strap is suitable for use with DORMA Double Action Floor Springs.
Code: DCAA300A
The Assa Abloy DC300A overhead door closer has adjustable power size EN 3-6, backcheck function, and is suitable for use on timber and metal fire doors.
Code: DCB2720
The Briton 2720BD.T.S.SES Cam Action Door Closer is an overhead door closer with slide channel that is suitable for universal door applications. It has an adjustable power size EN 2-5 and a silver finish.